NL44E 24V DC Contactor Relay
NL... contactor relays are used for switching auxiliary circuits and control circuits - Poles: 8-pole contactor relays (mechanicallylink ed contact elements available) The width of 8-pole devices is identical to that of 4-pole devices only the depth is increased - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available NL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.only the depth is increased - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available NL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
only the depth is increased - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available NL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
K
EC000196 - Contactor relay
EC000196 - Contactor relay
EC000196 - Contactor relay
EC000196 - Contactor relay
39121500
1 piece
86 mm
141 mm
51 mm
0.58 kg
3471522295811
box 28 piece
16.24 kg
CB_SE_66833A1
CCC_2012010304558126
CSA_1041746
1SBD250808U1000
1SBD250127E1002
GOST_POCCFRME77B07174
1SBC101003M5501
1SBD250808U1000
UL_110105E48139A
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air (Uc) -40 ... +70 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
3000 m
Shock Direction: B2 10 K40
Closed, Shock Direction: A 20 K40
Closed, Shock Direction: B1 15 K40
Closed, Shock Direction: C1 20 K40
Closed, Shock Direction: C2 14 K40
Open, Shock Direction: A 10 K40
Open, Shock Direction: B1 5 K40
Open, Shock Direction: C1 8 K40
Open, Shock Direction: C2 8 K40
Following EU Directive 2011/65/EU
4
4
Auxiliary Circuit 690 V
Main Circuit 690 V
Supply Circuit 50 60 Hz
acc. to IEC 60947-5-1, q = 40 °C 16 A
(220 / 240 V) 4 A
(24 / 127 V) 6 A
(380 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
Auxiliary Circuit - gG Type Fuses 10 A
1200 cycles per hour
(125 V) 0.55 / 69 A
(24 V) 6 / 144 A
(250 V) 0.3 / 75 A
(48 V) 2.8 / 134 A
(72 V) 1 / 72 A
acc. to UL/CSA 600 V
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
8 kV
> 20 million
6000 cycles per hour
DC Operation 24 V
Average Holding Value, from Warm State 3 W
Average Pull-in Value, from Cold State 3 W
Between Coil De-energization and NC Contact Closing 16 ... 27 ms
Between Coil De-energization and NO Contact Opening 10 ... 17 ms
Between Coil Energization and NC Contact Opening 20 ... 70 ms
Between Coil Energization and NO Contact Closing 50 ... 100 ms
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 m²
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Screw Terminals
44 mm
130 mm
78 mm
0.58 kg
1SBC100122C0202_Ch03
1SBC101003M5501
FPTE307873
1 piece
85364900